Logo ZutEnergoAudyt naprawy transformatorów
  • About us
  • News
    • Events
    • Articles
    • Conference
  • Offer
    • Transformer service and repairs
    • On-load tap changers
    • Diagnostics and measurements
    • High-voltage devices condition monitoring systems
    • Oil research and measurement laboratory
    • Other energy services
  • Projects
  • Career
    • Technician/Electrical Engineer
    • Sales Specialist
  • Contact
505 170 137
  • PL
  • EN
  1. Home
  2. Offer
  3. High-voltage devices condition monitoring systems
  4. Devices monitoring the condition of the turbogenerator

Urządzenia monitorujące stan turbogeneratora

Partial Discharge Testing

Partial discharge monitoring provides information regarding small electrical sparks that occur within insulation due to aging or deterioration. Iris Power solutions allow for planning maintenance requirements before insulation failures or short circuits occur.

Read more

Vibration Analysis of Stator Winding End-Windings

Stator Winding Endwinding Vibration caused by winding looseness and thermal cycling can lead to copper conductor cracking within the windings or failures caused by insulation wear. Iris Power solutions provide information regarding the location and severity of endwinding vibration to enable corrective action.

Read more

Leakage Test of Stator Wedge

Loose stator wedges can lead to coil vibration and stator insulation erosion. The Iris Power Stator Wedge Tightness Test provides consistent and quantitative means to identify the location and degree of stator wedge looseness, for the purpose of planning re-wedging or other necessary repairs.

Fluctuation of Magnetic Flux Study

Fluctuations in the rotor magnetic flux are a result of the deterioration of the rotor winding insulation, caused by mechanisms such as load changes, thermal aging, and contamination. Iris Power provides solutions for measuring magnetic flux in a generator, in order to plan maintenance requirements.

Czytaj więcej

Core Lamination Integrity Studies

The integrity of the stator core lamination can be degraded by thermal and mechanical stresses. The Iris Power EL CID test detects shorted laminations and is a globally accepted solution for determining maintenance needs.

Voltage Monitoring on the Shaft

Shaft voltage is induced in electric motors and generators due to rotor winding ground faults, surges caused by the rotor excitation system, magnetic generator components, and magnetic fields. Iris Power solutions provide the information needed to plan maintenance ahead of time, helping to avoid damage to generator bearings, shaft journals, couplings, and gears.

ROZWIĄZANIA MONITORINGU ON-LINE STANU TECHNICZNEGO TURBOGENERATORA

rozwinazania-monitoringu-on-line-stanu-technicznego-turbogeneratora.pdf

Logo

Zakład Usług Technicznych Energoaudyt Sp. z o.o.

ul. Napędowa 5, Milejowice
26-652 Zakrzew, Poland

Phone Numbers:
+48 48 334 19 11
+48 505 170 137

General inquiries:
info@zutenergoaudyt.com.pl
Customer service:
bok@zutenergoaudyt.com.pl

Energy services:

  • Serwis i remonty transformatorów
  • Podobciążeniowe przełączniki zaczepów
  • Diagnostyka i pomiary
  • Systemy monitoringu stanu urządzeń wysokiego napięcia
  • Inne usługi energetyczne

IMD
Cookies logo

Our website uses cookies and other techniques that allow us to remember and understand how visitors use the website. By continuing to use this site, you accept these terms.

Cookies close